The main points of maintenance and maintenance of Chinese medicine ultra -micro crushing machines

What are the main points of maintenance and maintenance of Chinese medicine ultra -micro crushing machines? Qingdao Youmingke Plel Machinery will explain separately.

Powder equipment display diagram

Maintenance of the super microcontroller of traditional Chinese medicine:

1. First check the power socket, plug, power cord to break off and break off, break off, break off, break off, break off, break off, break off, break off, and break off. If not, you can insert a power test machine.

2. When the motor does not rotate, and when the wheels can be rotated by hand, it can be determined that there is a capacity failure in the two startup capacitors of the machine. In this case, there are generally only new products.

3. Another situation is that it does not rotate by power. The external force can be rotated. However, a weak current sound is emitted in the motor, which is caused by a slight leakage of the capacitor. If the current is too loud, the motor cannot be started at all, and it is determined that it is caused by the short circuit of the capacitor. In the absence of professional instruments, the capacitance can be removed first, and the two leads are inserted into the zero -hiring thread jack of the municipal electricity. If the discharge spark can be emitted at this time, there is a loud \u0026 ldquo; Pap \u0026 rdquo; indicate that the capacitance can be used; if the spark and noise are weak, it means that the capacity of the capacitor has decreased, just replace or add a small capacitor. This method cannot be used if the capacitance has damaged the short circuit, and it must be replaced with new products with the same specifications.

Maintenance of super micro -crushing machines of Chinese medicine:

The general quality of super micro -crushing machines such in traditional Chinese medicine is very easy to damage, and daily maintenance is more important.

1. Check whether the lubrication of the bearings is good.

2. Check whether all fasteners are tight.

3. Check whether the transmission belt is installed correctly and the situation. If the belt is damaged, it should be replaced in time. When there is oil pollution on the belt or groove wheel, clean the rag in time.

4. Check whether the protective device is good. If the protective device is found to be unsafe, it should be excluded in time.

5. Check whether there are materials or other debris in the damaged cavity, and sometimes it should be cleaned.

6. Check whether the top head or the top rod is returned, and adjust whether the pad is installed correctly and tightly.